Anti-slip Product information Anti-slip Applications Anti-slip Online quotation form
Anti-slip Installation guidelines Case Study

 
Anti-slip Installation Guideline
 

Slip resistant flooring for ramps, stair treads, walkways, platforms, bridges & decking


The panels can be installed in any weather and can be used immediately after installation. They must always be fully supported. We recommend the following fixings:
 
 

Timber Fixing


Use four nails per unit 600mm long. nail should ideally be as close as possible to the edge ensuring they penetrate into sound timber. Alternatively stainless steel screws can be used for greater security.
 
 

Concrete Fixing


Panels should be predrilled & countersunk to accomodate zincplated or stainless steel anchors. Holes should be 1 mm larger then the screw diameter to allow for movement.
 
 

Open Mesh Fixing


Stainless steel or zinc plated Saddle Clips & domed headed bolts suitable in length for the depth of the existing mesh.
 
 

Steel Plate Fixing


Use No 8x20mm Self Tapping pan pozi stainless steel or Philips zinc plated screws.
 
 
Alternatively, Anti-slip can be glued to sound clean dry surfaces, using a suitable high strength gap-filling adhesive.
 
 
 